ELOTEST PL600 with EMDC
The distance of the sensor relative to the part being tested is the most decisive influencing factor for the sensitivity of eddy current testing. If the sensor distance cannot kept constant, 2 measures can be taken: By default, we deploy special distance compensation probes in combination with use of the electronical distance compensation from the Instrument PL600 which works for distance variations up to 1 mm (+/- 0,5mm).